Sign In | Join Free | My burrillandco.com
Home > Telecom Power System >

8KW 230Vac 4KW 115Vac Rectiverter Power System 48Vdc Integrated 2U 6kVA 1ph (CIOR0402.XXX)

Beijing Ding Ding Future Technology Co.Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 8KW 230Vac 4KW 115Vac Rectiverter Power System 48Vdc Integrated 2U 6kVA 1ph (CIOR0402.XXX) from wholesalers
     
    Buy cheap 8KW 230Vac 4KW 115Vac Rectiverter Power System 48Vdc Integrated 2U 6kVA 1ph (CIOR0402.XXX) from wholesalers
    • Buy cheap 8KW 230Vac 4KW 115Vac Rectiverter Power System 48Vdc Integrated 2U 6kVA 1ph (CIOR0402.XXX) from wholesalers
    • Buy cheap 8KW 230Vac 4KW 115Vac Rectiverter Power System 48Vdc Integrated 2U 6kVA 1ph (CIOR0402.XXX) from wholesalers
    • Buy cheap 8KW 230Vac 4KW 115Vac Rectiverter Power System 48Vdc Integrated 2U 6kVA 1ph (CIOR0402.XXX) from wholesalers

    8KW 230Vac 4KW 115Vac Rectiverter Power System 48Vdc Integrated 2U 6kVA 1ph (CIOR0402.XXX)

    Ask Lasest Price
    Brand Name : OEM
    Model Number : CIOR0402.XXX
    Certification : CE, UL
    Price : 1800 USD / 3500 USD
    Payment Terms : L/C, T/T
    Supply Ability : 500 sets per month
    Delivery Time : 8-10 weeks
    • Product Details
    • Company Profile

    8KW 230Vac 4KW 115Vac Rectiverter Power System 48Vdc Integrated 2U 6kVA 1ph (CIOR0402.XXX)

    8KW 230Vac 4KW 115Vac Rectiverter Power System 48Vdc Integrated 2U 6kVA 1ph (CIOR0402.XXX)


    Eltek Rectiverter Integrated 2U, 48VDC 6kVA 1ph systems with Smartpack 2 Touch and basic (part No.CIOR0402)


    Applications :


    The rectiverter 2U 19inch integrated system can be used as a stand alone system with bulk AC &DC output in industiral applications where a 230 /115Vac and 110Vdc back up is needed.


    The total output power for both AC and DC is limited to a total 8KW, AC and DC output limits can be set according to the connected load, where the limitation for AC load is set to max 6kVA and for DC load to max 4KW ,8KW.


    As additional options, the measuring and signaling can be widely extended with the I/Q monitor or Flexi monitor CAN nodes.


    TELECOM-MOBILE/WIRELESS


    · LTE/4G/WiMAX

    · Distributed antenna system

    · Broadband

    · Radio base stations/cell sites


    POWER UTILITIES


    · Low & High voltage switchgear

    · Transformer & SUB stations

    · Control & protection

    · SCADA system


    RAILWAY & METRO INFRASTRUCTURE


    · Control & protection

    · Signaling


    Key Features :

    l Compact design and simple installation

    l Single phase 230 or 115VAC input and output

    l 48Vdc input and output

    l Up to 4 rectiverter modules

    l 8KW total AC+DC output

    l Max 6kVA AC output

    l Max 4KW/ 8KW DC output

    l 1 or 2 pole AC distribution options

    l 1 Pole DC distribution option

    l Built in transfer technology


    Techinical Data:


    Models8 kW, 230 VAC4 kW, 115 VAC
    Product familyCIOR0402.1xxxCIOR0402.1xxx
    AC OUTPUT DATA
    Voltage (default) / (adjustable range) 1)230 VAC / 200-240 VAC115 VAC / 100-127 VAC
    Frequency (inverter mode – default)50 Hz (adaptive)60 Hz (adaptive)
    Frequency (inverter mode – settable)50 Hz, 60 Hz or last synced 50 / 60 Hz (adaptive)
    Power maximum (continuous / overload <15s)4800 W (6000 VA) / 8000 VA2400 W (3000 VA) / 4000 VA
    Current maximum (continuous / overload <15s)26 ARMS / 34,8 ARMS
    Current (maximum) quick trip (20ms)128 A (6 x nominal)
    Hold up (Voltage dips) (before switching to battery)5 ms5 ms
    THD< 1,5 % at resistive load
    ProtectionFuse in L, Hot pluggable, Varistor
    DC OUTPUT DATA
    Voltage (default) / (adjustable range)53,5 VDC / 43-58 VDC
    Power (maximum @nominal input)4800 W 2)2400 W 2)
    Current (maximum @VOUT ≤ 48 VDC)100 A 2)50 A 2)
    Current sharing (10 - 100% load)±5 % of maximum current from 10 to 100 % load
    ProtectionShort circuit proof, Over voltage shutdown, Reversed polarity and Fuse
    INPUT DATA
    AC Mains Input Voltage (range / LV disconnect)185-275 VAC / 170 VAC95-140 VAC / 85 VAC
    AC Current (maximum - depends on module type)32,8-46 ARMS 3)36,8-45,2 ARMS 3)
    Frequency (default: sync range)47-53 & 57-63 Hz57-63 & 47-53 Hz
    Frequency (settable: sync range)47-53 Hz, 57-63 Hz or both (adaptive)
    Power Factor / THD> 0,99 at 70% load or more / < 3,5 %
    DC Voltage nominal / extended range 4)45-58 VDC / 40-45 VDC
    DC Current (maximum)128 A / 180 A during overload (15 s)64 A / 90 A during overload (15 s)
    Input features

    Fuse in L and N, Hot pluggable, Varistor

    AC input individual screw terminals 4 mm2 for L, N & PE (4x single phase)

    OPTIONS
    Control and Monitoring (master unit)Smartpack2 Touch
    Control and Monitoring (basic unit)Smartpack2 Basic
    Controller CAN nodeI/O Monitor T2
    AC distributionAC output individual screw terminals 10 mm2 for L, N & PE (1x single phase)
    DC distributionDC bulk connection on 2x M6 bolt
    OTHER SPECIFICATION
    Efficiency> 96 % (mains mode), > 94 % (inverter mode)> 92 % (mains mode), > 91 % (inverter mode)
    Operating temperature-40 to +55 °C (-40 to +131 °F), humidity 5-95 % RH non-condensing
    Storage temperature-40 to +85 °C (-40 to +185 °F), humidity 0-99 % RH non-condensing
    Dimensions [W x D x H]482 x 400 x 89 mm (2U) (19 x 15,7 x 3,5 inch)
    Weight9,4 kg (20,7 lbs)
    DESIGN STANDARDS
    Electrical safetyEN 60950-1, EN 62040-1 UPS safety

    EMC

    ETSI EN 300 386 V2.1.1, FCC CFR 47 Part 15

    EN 62040-2

    EN 61000-6-1/-2/-3/-4/-5


    Environment

    ETSI EN 300 019: 2-1 (Class 1.2), 2-2 (Class 2.3) & 2-3 (Class 3.2)

    Normal operating conditions as per IEC 62040-3:2011 clause 4.2. Other operating conditions as per IEC 62040-3:2011 clause 4.3, must be advised

    RoHS 3 (2015/863/EU) and WEEE (2008/98/EC) compliant

    1) Output voltage ranges configured in factory and have individual keying in top chassis

    3) If DC port is overloaded pulling the voltage below 43 V the input current may increase above this level.

    2) AC load has priority. Maximum available DC output power and current is dependent on instant AC load and AC input voltage;

    i.e. maximum 3200 W / 66,4 A at full AC power and nominal input for 230 VAC.

    4) Reduced performance - no over load support, and for 200-240 VAC output THD will increased and maximum output power de- rates (to 970 W for 230 VAC @ 40 VDC)


    8KW 230Vac 4KW 115Vac Rectiverter Power System 48Vdc Integrated 2U 6kVA 1ph (CIOR0402.XXX)



    Related Products:


    8KW 230Vac 4KW 115Vac Rectiverter Power System 48Vdc Integrated 2U 6kVA 1ph (CIOR0402.XXX)8KW 230Vac 4KW 115Vac Rectiverter Power System 48Vdc Integrated 2U 6kVA 1ph (CIOR0402.XXX)

    8KW 230Vac 4KW 115Vac Rectiverter Power System 48Vdc Integrated 2U 6kVA 1ph (CIOR0402.XXX)8KW 230Vac 4KW 115Vac Rectiverter Power System 48Vdc Integrated 2U 6kVA 1ph (CIOR0402.XXX)

    8KW 230Vac 4KW 115Vac Rectiverter Power System 48Vdc Integrated 2U 6kVA 1ph (CIOR0402.XXX)

    Solutions

    We provide a complete solutions including site survey, propose professional plan according to customer’s request ,technical support, and maintenance service for Telecommunication Companies in and out of China. We have a competent team and a network of trusted Partners around the world.


    FAQ :

    1. How do you control the quality?

    A:All products before the shipment are simulated usage scenarios, load and full load and current sharing test to ensure the quality of the product.


    2. What is your minimum order quantity?

    A:There is no minimum order quantity, and one can also be done. The only difference is the price and schedule.


    3. Can you introduce your company?

    A:I am very honored. I will send you the company’s introduction document later to give you a more comprehensive and direct introduction to our company’s information.


    4. What are the advantages of your company?

    A:Adequate inventory, and supply guarantee for the subsequent renewal of supply, flexible provided according to different to different needs of customers, providing different solutions.


    5. Can i send samples?Report it to me along with the price?

    A:You can send samples, the samples are subject to large pride, and the freight needs to be borne by you.


    6. How do your company deal with the problem on quality?

    A:Our company has been doing this industry for almost 10 years. It has already had a certain reputation. We will carefully analyze it. If it is indeed our quality problem, you can rest assured that it will do things according to the contract agreement and will never let you have any after the worries, our service team will be happy to serve you.


    7 What about the quality ?

    A:100% original with new package. we will test each item before posted to make sure each item with good quality.


    8 How many months for guarantee ?

    A: 1 year quality guarantee


    9 How to deal with any inferior -quality goods ?

    A: Goods can be post by with our charge of post fee for any bad quality products within guarantee time.


    Quality 8KW 230Vac 4KW 115Vac Rectiverter Power System 48Vdc Integrated 2U 6kVA 1ph (CIOR0402.XXX) for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing Ding Ding Future Technology Co.Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)