Sign In | Join Free | My burrillandco.com
Home > Telecom Power System >

Rectiverter Eltek Telecom Power System Scalable 120kW 230/400VAC 3 Phase Big System

Beijing Ding Ding Future Technology Co.Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Rectiverter Eltek Telecom Power System Scalable 120kW 230/400VAC 3 Phase Big System from wholesalers
     
    Buy cheap Rectiverter Eltek Telecom Power System Scalable 120kW 230/400VAC 3 Phase Big System from wholesalers
    • Buy cheap Rectiverter Eltek Telecom Power System Scalable 120kW 230/400VAC 3 Phase Big System from wholesalers
    • Buy cheap Rectiverter Eltek Telecom Power System Scalable 120kW 230/400VAC 3 Phase Big System from wholesalers

    Rectiverter Eltek Telecom Power System Scalable 120kW 230/400VAC 3 Phase Big System

    Ask Lasest Price
    Brand Name : Eltek
    Model Number : CDEJ6042.xxxx
    Certification : CE.UL
    Payment Terms : L/C,T/T
    Supply Ability : 400 sets /month
    Delivery Time : 8-10 weeks
    • Product Details
    • Company Profile

    Rectiverter Eltek Telecom Power System Scalable 120kW 230/400VAC 3 Phase Big System

    Rectiverter Eltek Telecom Power System Scalable 120kW 230/400VAC 3 Phase Big System

    Eltek Rectiverter-Indoor system Scalable 120 kW system with optional A+B, AC input (CDEJ6042.xxxx)

    The scalable Rectiverter indoor system provides backup power for 400 VAC 3-phase or 230 VAC 1-phase loads, and 48 VDC power for DC loads and battery charging.


    Rectiverter Scalable System 120 kW

    The system has a maximum load capacity of 108 kW, which is dynamically variable to provide AC outputs up to 90 kVA / 72kW and also feed DC loads up to 72 kW with built in AC & DC distribution.
    When used in combination with the optional B-input (dual AC input) which eliminates the need for a traditional ATS (Automatic Transfer Switch), the Rectiverter indoor system represents the ultimate in flexibility and scalability.


    Key features

    400 VAC 3 phase (Y) input

    400 VAC 3 phase (Y) output

    48 VDC input/output

    Max 90 kVA / 72 kW AC output

    Max 72 kW DC output

    AC Distribution

    DC distribution option

    A+B option (dual AC input)

    LVBD option

    Up to 4 battery strings

    Built in transfer technology

    150% overload capability, 15S

    600% quick trip current 20 ms

    Hot pluggable

    Smartpack2 controller

    Operates in paralell with Flatpack2 rectifiers

    Global compliance

    Patented HE technology


    SINGLE LINE DIAGRAM 120 KW + 108 KW B-INPUT



    Parameters :



    Models / ordering information
    120 kW + 108 kW B-input
    Product family
    CDEJ6042.xxxx
    AC OUTPUT DATA
    Voltage (default) / (adjustable range)1)
    400 VAC 3 phase (Y) / 346-415 VAC
    Frequency (default inverter mode)
    50 Hz (adaptive)
    Frequency (set-able inverter mode)
    50Hz, 60Hz or last synced 50/60Hz (adaptive)
    Power maximum (continuous / overload (<15s) )
    72 kW (90 kVA) / 120kVA
    Current maximum/phase (continuous / overload (<15s) )
    130 ARMS / 174 ARMS
    Current (maximum) Quick trip/phase (20ms)
    640 A (6 x nominal)
    Hold up (Voltage dips) (before switching to battery)
    > 5 ms @ 72 kW load
    THD
    < 1.5 % at resistive load


    Output features

    Module: Fuse in L and N , Hot pluggable

    1 pole or 3 pole AC distribution (connection directly on MCB)

    Max breaker capacity according to recommended max breaker for rectiverter module

    DC OUTPUT DATA
    Voltage (default) / (adjustable range)
    53.5 VDC / 43 - 58 VDC
    Power (maximum @nominal input)
    72 kW 2)
    Current (maximum @VOUT ≤ 48 VDC)
    1500 A 2)
    Hold up time, maximum output power
    >10ms; VOUT > 41 VDC
    Output features
    Short circuit proof, Over voltage Shutdown
    INPUT DATA
    AC Mains Input Voltage(3 phase Y)
    320-475 VAC,
    AC Current/phase(at nominal output voltage) (depending on module type)140-240 ARMS 4)
    Frequency (default: sync range)
    47-53 & 57-63 Hz
    Frequency (set-able: sync range)
    47-53 Hz, 57-63 Hz or both (adaptive)
    Power Factor / THD
    > 0.99 at 50% load or more / < 3.5%
    DC Voltage nominal / extended range (no overload)3)
    45 - 58 VDC / 40 - 45 VDC
    DC Current (maximum)
    1920 A / 2700 A during overload (15s)
    Input features

    Module : Fuse in L and N, Hot pluggable, Varistor, Hot pluggable

    AC input individual screw terminals 150 mm2 for L1-L3, N & PE

    BATTERY BREAKER
    1-pole battery breaker2*TPS 2 holder (800-1600 A)4*TPS 00 holder (250-600 A)
    OPTIONS
    B-input maximum power (with FP2 HE, 2 kW rectifiers)
    72 kW
    B-input maximum power (with FP2 HE, 3 kW rectifiers)
    108 kW
    DC distribution (connection directly on breaker)
    1-125 A, 1 pole breaker (max 30 pc 18 mm, max 20 pc 27 mm)
    LVBD (1-pole)
    1800 A
    OTHER SPECIFICATION
    Efficiency>96% (mains mode (AC/AC and AC/DC)), >94% (inverter mode (DC/AC))
    Protection ClassIP 20

    Operating temperature-40 to +55°C (-40 to +131°F), humidity 5 - 95% RH non-condensing
    Storage temperature-40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing
    Dimensions[WxDxH] / Weight1200 x 600x 2000mm (23,7 x 23,7 x 78,8”) / 300 kg (1100 lbs)
    DESIGN STANDARDS
    Electrical safetyEN 60950-1, EN 62040-1 UPS safety
    EMC

    ETSI EN 300 386 V.1.6.1, FCC CFR 47 Part 15

    EN 61000-6-1 /-2/-3/-4, EN62040-2



    Environment

    ETSI EN 300 019: 2-1 (Class 1.2), 2-2 (Class 2.3)

    Normal operating conditions to be as per IEC/EN 62040-3:2011 clause 4.1 RoHS (2011/65/EU) and WEEE (2002/96/EC) compliant

    1) Output voltage ranges configured in factory and have individual keying in top chassis

    3) 40 - 45 VDC: reduced performance - no power boost and increased voltage THD on AC output.

    2) AC load has priority. Maximum available DC output power and current is dependent on instant

    AC load and AC input voltage; i.e maximum 48kW/1000 A at full AC power and nominal input for 230VAC.

    4) If DC voltage is pulled below 43V the input current may increase above this level



    * The indoor Rectiverter Cabinet with AC &DC feed in one cabinet

    Rectiverter Eltek Telecom Power System Scalable 120kW 230/400VAC 3 Phase Big System


    Rectiverter Eltek Telecom Power System Scalable 120kW 230/400VAC 3 Phase Big System



    Related Products :

    Rectiverter Eltek Telecom Power System Scalable 120kW 230/400VAC 3 Phase Big System




    Rectiverter Eltek Telecom Power System Scalable 120kW 230/400VAC 3 Phase Big SystemRectiverter Eltek Telecom Power System Scalable 120kW 230/400VAC 3 Phase Big System

    Rectiverter Eltek Telecom Power System Scalable 120kW 230/400VAC 3 Phase Big System


    Solutions

    For telecom enterprises at home and abroad, we provide a comprehensive range of services. From on - site inspections to gain a practical understanding of the situation, to the formulation of professional plans based on customer demands, and then to the resolution of technical issues and the regular maintenance of equipment, we cover it all. With a highly qualified team and a network of reliable partners worldwide, we guarantee the efficiency and reliability of our services.



    FAQ :

    1.How do you supervise product quality?

    A: We have a comprehensive quality control system in place. Before products are shipped, they are tested in scenarios that replicate real - world usage, including load, full - load, and current sharing tests, to ensure that only high - quality products are delivered.


    2.Is there a minimum quantity for placing an order?

    A: We don't impose a minimum order quantity. You can order just one item or more. But please note that the order quantity will impact both the price and the delivery time.


    3.Can you introduce your company briefly?

    A: Sure. I'll send you our company's detailed introduction document soon. It will give you a complete picture of our company, including our business scale, technical capabilities, and market position.


    4.What are the competitive edges of your company?

    A: Our company is known for its sufficient inventory, which ensures a smooth supply for future orders. Also, we offer flexible services, customizing solutions according to different customer demands.


    5.Can I ask for samples and get a price quotation?

    A: Samples are available. The price of samples is the same as the bulk price, and you will be responsible for the sample shipping fee.



    Rectiverter Eltek Telecom Power System Scalable 120kW 230/400VAC 3 Phase Big System

    Quality Rectiverter Eltek Telecom Power System Scalable 120kW 230/400VAC 3 Phase Big System for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing Ding Ding Future Technology Co.Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)