    Meanwell DPR Series Rectifier Module 3200W DPR-3200-24 DPR-3200-48 DHP-1UT DBR-3200

    Ask Lasest Price
    Brand Name : MEAN WELL
    Model Number : DPR-3200-24 /DPR-3200-48
    Certification : CE
    Price : USD 299
    Payment Terms : L/C, T/T
    Supply Ability : 3000 pieces per month
    Delivery Time : 8-10 weeks
    • Product Details
    • Company Profile

    Meanwell DPR Series Rectifier Module 3200W DPR-3200-24 DPR-3200-48 DHP-1UT DBR-3200

    Meanwell DPR Series Rectifier Module 3200W DPR-3200-24 DPR-3200-48 DHP-1UT DBR-3200


    Mean Well DPR Series 3200W DPR-3200-24 DPR-3200-48 DHP-1UT DBR-3200


    Wattage :


    3200


    Features :

    Complete rack mountable front end solution: rectifier and charger

    1U low profile

    19 inch rack shelf available


    Technical


    MODELDRP-3200-24DRP-3200-48

    OUTPUT

    DC VOLTAGE24V48V
    RATED CURRENT133A67A
    CURRENT RANGE0 ~ 133A0 ~ 67A
    RATED POWER3192W3216W
    RIPPLE & NOISE (max.) Note.2,3300mVp-p480mVp-p
    VOLTAGE ADJ. RANGE23.5 ~ 30V47.5 ~ 58.8V
    VOLTAGE TOLERANCE Note.4±1.0%±1.0%
    LINE REGULATION±0.5%±0.5%
    LOAD REGULATION±0.5%±0.5%
    SETUP, RISE TIME1500ms, 60ms/230VAC at full load
    HOLD UP TIME (Typ.)16ms / 230VAC at 75% load 9ms / 230VAC at full load

    INPUT

    VOLTAGE RANGE Note.590 ~ 264VAC 127 ~ 370VDC
    FREQUENCY RANGE47 ~ 63Hz
    POWER FACTOR (Typ.)0.97/230VAC at full load
    EFFICIENCY (Typ.) Note.693.5%94.5%
    AC CURRENT (Typ.) Note.517A/230VAC
    INRUSH CURRENT (Typ.)COLD START 55A/230VAC
    LEAKAGE CURRENT<1.5mA / 230VAC

    PROTECTION


    OVERLOAD

    105 ~ 115% rated current
    Protection type : Constant current limiting, shut down O/P voltage after 5 sec. After O/P voltage falls, re-power on to recover

    OVER VOLTAGE

    31.5 ~ 37.5V63 ~ 75V
    Protection type : Shut down o/p voltage, re-power on to recover
    OVER TEMPERATUREShut down o/p voltage, recovers automatically after temperature goes down

    FUNCTION


    OUTPUT VOLTAGE PROGRAMMABLE(PV)

    Adjustment of output voltage is allowable to 50 ~ 125% of nominal output voltage Please refer to the Function Manual in following pages
    CONSTANT CURRENT LEVEL PROGRAMMABLE(PC)Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual in following pages
    REMOTE ON-OFF CONTROLBy electrical signal or dry contact Power ON:short Power OFF:open. Please refer to the Function Manual in following pages
    REMOTE SENSECompensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual in following pages
    AUXILIARY POWER5V @ 0.3A, tolerance ±10%, ripple 150mVp-p, 12V @ 0.8A, tolerance ±10%, ripple 450mVp-p
    ALARM SIGNALIsolated TTL signal output for T-Alarm, AC-OK and DC-OK. Please refer to the Function Manual in following pages

    ENVIRONMENT

    WORKING TEMP.-30 ~ +70℃ (Refer to "Derating Curve")
    WORKING HUMIDITY20 ~ 90% RH non-condensing
    STORAGE TEMP., HUMIDITY-40 ~ +85℃, 10 ~ 95% RH non-condensing
    TEMP. COEFFICIENT±0.03%/℃ (0 ~ 50℃)
    VIBRATION10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

    SAFETY & EMC

    (Note 9)

    SAFETY STANDARDSUL62368-1, CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
    WITHSTAND VOLTAGEI/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
    ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH

    EMC EMISSION

    ParameterStandardTest Level / Note
    ConductedBS EN/EN55032 (CISPR32)Class B
    RadiatedBS EN/EN55032 (CISPR32)Class A
    Harmonic CurrentBS EN/EN61000-3-2-----
    Voltage FlickerBS EN/EN61000-3-3-----

    EMC IMMUNITY

    BS EN/EN55024, BS EN/EN61000-6-2
    ParameterStandardTest Level / Note
    ESDBS EN/EN61000-4-2Level 3, 8KV air ; Level 2, 4KV contact
    RadiatedBS EN/EN61000-4-3Level 3
    EFT / BurstBS EN/EN61000-4-4Level 3
    SurgeBS EN/EN61000-6-22KV/Line-Line 4KV/Line-Earth
    ConductedBS EN/EN61000-4-6Level 3
    Magnetic FieldBS EN/EN61000-4-8Level 4
    Voltage Dips and InterruptionsBS EN/EN61000-4-11

    >95% dip 0.5 periods, 30% dip 25 periods,

    >95% interruptions 250 periods


    OTHERS

    MTBF535.5K hrs min. Telcordia SR-332 (Bellcore) ; 44.6K hrs min. MIL-HDBK-217F (25℃)
    DIMENSION325*107*41mm (L*W*H)
    PACKING2.65Kg;4pcs/11.6Kg/0.87CUFT
    NOTE

    1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

    2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

    3. Under variable load application or parallel operation ripple of the output voltage may be higher than the SPEC at light load condition. It will go back to normal ripple level once the output load is more than 5%.

    4. Tolerance : includes set up tolerance, line regulation and load regulation.

    5. Derating may be needed under low input voltages. Please check the derating curve for more details.

    6. The efficiency is measured at 75% load.

    7. If use PV signal to adjust Vo, under certain operating conditions, ripple noise of Vo might slightly go over rating defined in this specification.

    8. Output will shut down after O/P voltage is below < 80% of Vset for 5 sec, re-power on to recover.

    9. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 600mm*900mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)

    10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}.

    ※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx



    Meanwell DPR Series Rectifier Module 3200W DPR-3200-24 DPR-3200-48 DHP-1UT DBR-3200


    Meanwell DPR Series Rectifier Module 3200W DPR-3200-24 DPR-3200-48 DHP-1UT DBR-3200


    Meanwell DPR Series Rectifier Module 3200W DPR-3200-24 DPR-3200-48 DHP-1UT DBR-3200Meanwell DPR Series Rectifier Module 3200W DPR-3200-24 DPR-3200-48 DHP-1UT DBR-3200

    Meanwell DPR Series Rectifier Module 3200W DPR-3200-24 DPR-3200-48 DHP-1UT DBR-3200


    Solutions
    We provide a complete solutions including site survey, propose professional plan according to customer’s request ,technical support, and maintenance service for Telecommunication Companies in and out of China. We have a competent team and a network of trusted Partners around the world.

    FAQ :
    1. How do you control the quality?
    A:All products before the shipment are simulated usage scenarios, load and full load and current sharing test to ensure the quality of the product.

    2. What is your minimum order quantity?
    A:There is no minimum order quantity, and one can also be done. The only difference is the price and schedule.

    3. Can you introduce your company?
    A:I am very honored. I will send you the company’s introduction document later to give you a more comprehensive and direct introduction to our company’s information.

    4. What are the advantages of your company?
    A:Adequate inventory, and supply guarantee for the subsequent renewal of supply, flexible provided according to different to different needs of customers, providing different solutions.

    5. Can i send samples?Report it to me along with the price?
    A:You can send samples, the samples are subject to large pride, and the freight needs to be borne by you.

    6. How do your company deal with the problem on quality?
    A:Our company has been doing this industry for almost 10 years. It has already had a certain reputation. We will carefully analyze it. If it is indeed our quality problem, you can rest assured that it will do things according to the contract agreement and will never let you have any after the worries, our service team will be happy to serve you.

    7 What about the quality ?
    A:100% original with new package. we will test each item before posted to make sure each item with good quality.
    8 How many months for guarantee ?
    A: 1 year quality guarantee
    9 How to deal with any inferior -quality goods ?
    A: Goods can be post by with our charge of post fee for any bad quality products within guarantee time.

    Meanwell DPR Series Rectifier Module 3200W DPR-3200-24 DPR-3200-48 DHP-1UT DBR-3200



    Meanwell DPR Series Rectifier Module 3200W DPR-3200-24 DPR-3200-48 DHP-1UT DBR-3200

    Quality Meanwell DPR Series Rectifier Module 3200W DPR-3200-24 DPR-3200-48 DHP-1UT DBR-3200 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing Ding Ding Future Technology Co.Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)